NEWS EVENTS CAREERS ERGIL WORLDWIDE

Industrial Silencers

Industrial Silencers

Industrial Noise Reduction Systems

Industrial silencers and mufflers are used to control and avoid the unwanted negative noise effect caused by a wide range of industrial process. Some of these areas consist of engines, compressors, generators, and blowers. Often industries such as the power, oil and gas, petrochemical, refinery and pulp & paper markets requires faces negative effect of noise related issues. In order to avoid health, safety and environmental issues, ERGIL designs, fabricate and install various kind of silencers and muffles; such as

Industrial Silencers

Blow Off Silencers (Vent Silencers)

Industrial Mufflers

Exhaust Silencers

* Pipeline Compressor Station Silencer with ERGIL StorageTech Flame Arrester

 

 

 


 

 

 

Brine Flash Tank Silencers & Weir Boxes

It is possible to explain this section of this context by exemplifying process of designing, fabricating and delivering of 13 silencers & 13 weir boxes to Zorlu Energy Group's Kizildere III - Geothermal Power Generation project, holding a big importance to the development of alternative energy sector in Turkey and international arena in terms of being a vital project to meet approximately 800,000 dwellings' electricity needs by increasing production capacity to 165 MW/.

 
 

Fig.1. ERGIL Silencer & Weir Box to be dispatched

Brine flash tank silencers are used to minimize extreme loud level that is created during the process of flashing geothermal brine at atmhospheric pressure and seperates vapor and brine (thermal water).

Weir boxes are used when tanks are filled with geothermal water and the silencer quietens the process as the steam and steam fluids which come out of the double sludge system are removed and the geothermal water is then transferred to the liquid weir boxes, where level and flow measurements are carried out.

ERGIL's brine flash tank silencers (dia 3800mm) and weir boxes (4230x1800x1229mm) are designed as per ASME Sec. VII Div. 1. & AWWA D100, and painted with high temperature endured Aluminium based, considering the extreme hot vapor and water conditions after quality controls of welding, assembling, nozzle orientation, painting and good practices by our experts. The construction material of ERGIL's silencers and weir boxes is carbon steel. ERGIL's silencers and weir boxes are easy to load and assembly and they provide effective solutions to increase the production of needed electrical energy capacity.

How effectively does geothermal help in improving air quality and decreasing greenhouse gas emissions?

'At geothermal power plants, billows seen rising from cooling towers are composed of water vapor or steam, not burned fuel or smoke emissions, and are caused by the evaporative cooling system. A binary or flash/binary geothermal plant produces nearly zero air emissions; air emission levels at dry steam plants are considered to be slightly higher because even without human intervention, geothermal systems already contain naturally-occurring dissolved gases

 

 

Fig. 2. Silencers under construction at ERGIL Factory

How do geothermal developers control noise levels?

The purpose of the Silencer is to significantly reduce the sound levels caused by the acoustical energy flowing in the discharge piping of the turbine, without affecting turbine performance and plant output. The purpose of the Weir Box is when Tanks are filled with geothermal water and the silencer quietens the process as the steam and steam fluids which come out of the double sludge system are removed and the geothermal water is then transferred to the liquid weir boxes, where level and flow measurements are carried out. ‘’The final product not only addressed a technical issue but also helped the Zorlu Energy Group effectively respond to community concern about noise levels from the plant.''    

 

                              Fig. 4. Field-installed ERGİL Silencers & Weir Boxes

 

SERVICES OFFERED BY ERGIL

Designİng and Engineering of Silencers and Weir Boxes

ERGIL's brine flash tank silencers (dia 3800mm) and weir boxes (4230x1800x1229mm) are designed as per ASME Sec. VII Div. 1. & AWWA D100, and painted with hight temputure enduranced Aluminium Internzic 22, considering the extreme hot vapor and water conditions after quality controls of welding, assembling, nozzle orientation, painting and good practices by our experts.

Material Specifications and Key Feautres

The construction material of ERGIL's silencers and weir boxes is carbon steel. ERGIL's silencers and weir boxes are easy to load and assembly and they provide effective solutions to increase the production of needed electrical energy capacity.

Inspection of Silencers and Weir Boxes

Our QC special Inspectors are expertise in all of most recent national regulations and international design requirements.

We usually are kindly recommended to invite our experienced supervisor during your first site operations. 

For more information, please WATCH our short silencer video,

 

Documentation:

Testimonials
  • Elsewedy Electric PSP

    Conducting business with ERGIL in the floating suction unit was a smooth process. Professional engineering - Read more

  • Aegis Logistics Ltd. States

    We feel happy to have been introduced to a team of professionals for our requirement of Internal - Read more

  • IE Immanuel Engineering Pte.

    While working with ERGIL, response has always been swift and guaranteed, whether it’s a working day or an official - Read more

  • Tecnovent SL

    We are glad to grow and expand together with ERGIL through the national territory and part South America. We - Read more